DCRV12
The highly compact base station has 12-24 VDC inputs, 12 outputs (4 relays, 8 MOSFET), and an available expansion board that can provide additional outputs or other features.
Technical data
Performance of the General Safe Stop function (GSS)
SIL 2 / PL d; cat. 3
Power supply
12-24 VDC
Antenna
internal
external optional
external optional
Max number of Optional Boards
1
Max number of outputs
12
Commands rated current
5 A (30 VDC)
Rated current of STOP / Safety outputs
5 A (30 VDC)
Protection degree
IP65 (Enclosure type 4)
Operating and storage temperature
operating: (-20 °C) ÷ (+70 °C) / (-4 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+70 °C) / (-40 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+70 °C) / (-40 °F) ÷ (+158 °F)
Connecting interfaces
cable gland
plug 16 and 24 pin
plug 16 and 24 pin
Dimensions
150x134.5x60 mm (5.9x5.29x2.36 in)
Weight
1 kg (2.2 lb)
Logistics & Transport