WC-Q+

WC-Q+

The WC-Q+ cable control unit can house 8 linear joysticks and up to 3 multi-axis joysticks.
The data feedback function provides important information about the machine status on a customizable 2.8" TFT LCD color graphic display, through 32 signal LEDs, or on a 4.3" color display (CODESYS/Linux programmable). Up to 8 digital outputs, up to 8 proportional PWM outputs (4 axes, bi-directional), and up to 2 proportional voltage outputs are available. It features a serial port for field bus (CANopen), 4 digital inputs, and a removable power keyswitch.

Accessories
Shoulder harness
Waist belt

Options
4.3" color display
2.8" color display
Customizable 32-LED matrix
High-Efficiency LED panel
Harting multi-pin connector
10- or 19-pole Souriau circular connector
M12 circular connector
Output with cable gland and multi-pin cable output

STOP and EMERGENCY STOP
Each cable control unit has a red stop button (STOP). With an appropriate cable connection, a stop button (rated current up to 2 A, 30 VDC) can be combined with machine safety circuits to be used as an emergency stop button (EMERGENCY STOP).
A “stop device” is defined as a manually commanded device that stops the machine in safe conditions, while an “emergency stop device” imposes an emergency stop, halting dangerous operations of a machine in an emergency. When a button fulfills an emergency stop function as well it is colored red with a yellow background. The choice of how this button is configured is based on the application requirements and a risk assessment of the machine.

Technical data

Power supply
8-30 VDC
Max number of outputs
up to 8 digital
up to 8 proportional (PWM)
up to 2 proportional (voltage)
1 CAN
Rated current of proportional outputs
PWM: 2 A (30 VDC)
Voltage: 10 mA (28 VDC)
Rated current of digital outputs
2 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1)
up to PL e, cat.4
Number of digital input
4
Protection degree
IP65 - NEMA 4
Dimensions
309x170x182 mm
12.2x6.7x7.2 in
Weight
2.4 kg
5.3 lb