Receiving unit with 12 analogue outputs and 64 digital outputs via CANopen interface, 4 MOSFET digital outputs. Connecting interfaces with M12 circular connectors, 10-pin reduced plug or cable gland. Internal antenna or external antenna as an option.

Technical data

Power supply
8-30 VDC
Antenna
Internal antenna; External optional with 1 or 5 meters extension cord
Max number of outputs
12 analog
64 digital
4 mosfet digital outputs
Rated current of STOP / Safety outputs
SO_1 = 2 A (30 VDC)
SO_2 = 2 A (30 VDC)
Rated current of digital outputs
2 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061)
up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061)
up to PL d, cat. 3 / SIL 2
Protection degree
IP65 (NEMA 4)
Operating and storage temperature
operating: (-25 °C) ÷ (+70 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Connecting interfaces
Customizable - possible solutions include M12 circular connector, 10-pin reduced plug, M12 connector (8+5pin), cable gland
Dimensions
144 x 162 x 63 mm
5.67 x 6.38 x 2.48 in
Weight
650 g